Impact Resistant of Various Interior Claddings for ICFSystemTest Procedure: ASTM D5420 Standard Test Method for Impact Resistance (Gardner Impact tester) Substrate: 1.5lbs density EPS Foam |
|||
| Product | Penetration depth | Impact energy 8.13 joules (72 inch/lbs) | Factor improvement over Type X |
| mm | Kfg-cm | ||
| Type X Sheetrock 15mm (5/8") | 7.11 | 82.95 | 1.0 |
| NG Hi impact FireShield 15mm | 4.82 | 82.95 | 1.5 |
| USG Hi impact VHI 15mm | 3.80 | 82.95 | 1.9 |
| PlasterMax Thin Coat 6mm (1/4") | 1.52 | 82.95 | 4.7 |
| BallistiCrete 12mm (1/2") | 0.50 | 82.95 | 14.0 |